I'm running SCS 9.5.3 and when I am in the editor, purely clicking on the left hand cue list (to view the cue's parameters), I am getting the following error:
'Run time Error'
2147220988 (80040204)
Attempt to add rows with no columns
It happens when I click on a midi send cue with a timebased start...and I think(?!) it also happened when clicking on a timebased playlist. It then shuts scs down completely, and on re loading it, if I do the same thing the fault doesn't occur.
My theatre machine is running Windows XP home, and my laptop is running Windows Vista Home premium...both have the same problem.
Run Time error (fix in 9.5.4)
-
- Site Admin
- Posts: 3632
- Joined: Sun Jul 24, 2005 8:58 am
- Location: Brisbane, Queensland, Australia. TZ:GMT+10
- Contact:
Re: Run Time error
What I expect is happening is you are using a Time Profile that doesn't exist in your Production Properties. SCS should, of course, prevent that happening. Could you email me your cue file (the .scs file)?
-
- Site Admin
- Posts: 3632
- Joined: Sun Jul 24, 2005 8:58 am
- Location: Brisbane, Queensland, Australia. TZ:GMT+10
- Contact:
Re: Run Time error
Problem found - I'll issue a fix shortly. The error occurs if you:
- Open the Editor and click on a Time Based Cue (or set a cue to Time Based), then
- Close the Editor, then
- Re-open the Editor and click on a Time Based Cue (or set a cue to Time Based).