[Resolved] DMX universe selection

Post bug reports here
Post Reply
Boswell
Posts: 227
Joined: Sat Jan 19, 2008 8:51 pm
Location: Southport, NW UK
Contact:

[Resolved] DMX universe selection

Post by Boswell » Sat Dec 03, 2016 12:20 am

Hi Mike
Using a ENTTEC USB Pro Mk2, SCS 11.5.2.2 (x64), Pro Plus

Any DMX command I send on DMx1 is also sent on DMX2 and vice versa

Any thoughts?

Diagnostic & Cue file attached
Attachments
Test.zip
(4.75 KiB) Downloaded 45 times
regards
Boswell
__________________________________________________________________________________________________________
Sound Dept
Southport Little Theatre
PR9 0PA
UK

Mike Daniell
Site Admin
Posts: 3630
Joined: Sun Jul 24, 2005 8:58 am
Location: Brisbane, Queensland, Australia. TZ:GMT+10
Contact:

Re: DMX universe selection

Post by Mike Daniell » Sat Dec 03, 2016 8:51 am

I'll email you a tracing version that will trace what DMX values are being sent. I've run your cue file here and it works correctly - sending DMX value 13 (=5%) to channel 1 on port 1, and sending what SCS deems to be the current values (all 0) to all other channels on port 1 and to all channels on port 2. If I insert an extra cue before your cue, to send values to a couple of channels on port 2, then this also works correctly, and then when your cue is played it sends 13 to channel 1 on port 1, and re-sends the latest values (from my inserted cue) to the channels on port 2.
Mike Daniell
Show Cue Systems Pty Ltd
mike@showcuesystems.com
Image

Boswell
Posts: 227
Joined: Sat Jan 19, 2008 8:51 pm
Location: Southport, NW UK
Contact:

Re: DMX universe selection

Post by Boswell » Tue Dec 13, 2016 3:05 am

Problem solved!!
Faulty breakout cable with the Enttec, replaced and then faulty operator action when testing! (ie me)
No faults with SCS at all and many thanks to Mike for his help and patience
regards
Boswell
__________________________________________________________________________________________________________
Sound Dept
Southport Little Theatre
PR9 0PA
UK

Post Reply